Introduction:
-
- DH48S-2Z is a preset timing relay, which has two sets of normally open and normally closed contacts. For the normally closed contact, once the time is set, it will continuously power the load until the set time is over, while the normally open contact does the opposite.
- The setting time range can be from a minimum of 0.01 seconds to a maximum of 99 hours and 99 minutes.
- It is a non-repeating time delay, if you want a cyclic timer relay please check out our DH48S-S relay.
- DH48S-2Z has two installation methods: panel mounting(with a clamp) and DIN rail mounting(with the PF083A relay socket). You can choose the most suitable mounting method by yourself.
- The two contact capacity is 5 amps@220VAC, which can directly drive 800W resistive load. If a higher power load needs to be operated, an AC contactor or AC SSR can be used.
- Want to get DH48S-2Z DPDT Time Delay Relay pricing or technical support from us, the time delay relay manufacturer? Fill out the form below to contact us today!
DH48S-2Z Timer Wiring:
Speficications:
Model | DH48S-2Z |
Working voltage | 36, 110, 220 or 380 Vac, 50/60 Hz; 12Vac/Vdc, 24Vac/Vdc |
Delay time | 0.01S to 99H99M |
Contact form | On-delay DPDT |
Tolerance | -15%-10% at AC and -10%-10% at DC of rated supply voltage |
Power consumption | 2W max |
Setting method | Dial switch |
Indication method | 8-segment 4-digital display |
External dimensions | 48x48x110 mm(with relay socket) |
Contact rating | 5A@220Vac, 5A@28Vdc |
Repeat accuracy | ±0.3%, ±0.05 sec |
Setting error | ±0.5%, ±0.05 sec |
Termination | 8 pins |
Mounting | Panel or DIN rail mounting |
Mechanical life | 1x10^6 |
Electrical life | 1x10^5 |
Operating temperature | 0 to 50 °C |
Operating humidity | 95% RH max, non-condensing |