200 mm Protection Height Safety Light Curtain Sensor Introduction:
- Lorentzzi® 200 mm protection height safety light curtain sensor is designed for protection against small machinery.
- The working principle is very simple and easy to understand. When the infrared light between the safety light curtain sensor transmitter and receiver is blocked, the output will be activated to achieve specific control requirements, such as shutdown, alarm, etc.
- The output of this safety light curtain can be selected as a normally closed transistor PNP or NPN output, or a normally closed relay output. The response time of transistor output (20 ms) is faster than that of relay output (30 ms). The output can be selected as single channel or dual channel, and dual channel output is safer.
- The beam spacing can be selected as 10.0 mm, 20.0 mm or 40.0 mm. For the detection of small objects such as fingers, please use the 10.0 mm beam spacing; for the detection of medium to large objects, please choose the other two. Or you can contact us for advice.
- We can also provide other protection height safety light curtains, the protection height can be 60 mm, 100 mm, 360 mm, 1000 mm, 1200 mm and 1400 mm etc.
- If you would like to know the latest prices for our safety light curtains, please fill out the form at the bottom to contact us now!
5 Steps To Choose A Safety Light Curtain?
- Selecting Optical Axis Spacing:
– 10 mm optical axis spacing is used for finger protection or other small objects.
– 20 mm optical axis spacing is used for palm protection or protection of objects larger than 20 mm.
– 40 mm optical space spacing is used for arm protection or for protecting objects larger than 40 mm. - Selecting Number of Optical Axes: The number of optical axes, or light beams, is determined by the height of the emitter and receiver, and can range from 7 to 500 beams.
- Selecting Protection Width: Lorentzzi® safety light curtain protection width can be 0.1 mm to maximum 3000.0 mm.
- Choosing Installation Method: The installation method can be side installation or top/bottom installation.
- Output options: Lorentzzi® safety light curtain outputs can be single-channel PNP, NPN, or relay outputs, or dual-channel PNP, NPN, or relay outputs.
Specifications:
| Protection height | 200 mm |
| Beam distance | 10 mm/20 mm/40 mm |
| Beam quantity | 24/12/6 |
| Working voltage | 24 VDC±20% |
| Power consumption | 5 W |
| Response time | <10 ms |
| Insulation resistance | ≥100 MΩ |
| Output | PNP, NPN, Relay |
| Protection distance | 0.1-5.0 m, 0.1-10.0 m, 0.1-15.0 m, 0.1-20.0 m |
| Working environment temperature | -10℃~55℃ |
| Storage environment temperature | -25℃~70℃ |
| Working environment humidity | <85% when temperature is 25℃ |
| Output current | 200 mA |
| Anti-light interference | 10000 Lux (incident angle I>5°) |
| Dielectric strength | AC 1500 V 60 S, No breakdown or flicker |
| Type | Through beam type |
| Cross-sectional size | 35*50 mm |